Finding where the money goes
Setting a hub up by talking to it is one thing; the other is what the records are worth once they are there. This is a session on a hub that has been measuring for a while. → Set up a hub by talking to it
Read it for the shape, not the figures. The amounts are one household's, and what matters is which questions the hub can answer, which ones it answers only partly, and where it says so itself.
The session
You: My bill is higher than last year and I don't know why. Where is the money going?
Assistant: I compared the last 30 days with the same 30 days a year ago, from your hub's records.
last year this year change Main supply, kWh 356 412 +56 Cost, EUR 109.80 127.40 +17.60Where the extra 56 kWh came from:
Water heater 112 -> 148 kWh (+36) Kitchen 58 -> 61 kWh (+3) Washing machine 23 -> 24 kWh (+1) Everything else 163 -> 179 kWh (+16)Two thirds of the increase is the water heater. Shall I look closer?
You: Yes. But it was colder this November, maybe that's all it is?
Assistant: Partly. This is from outside the hub: a public weather archive puts this November about 2 °C colder than last. Colder inlet water makes a heater work more, but that usually explains a few percent, not a third.
The hub shows something weather does not explain. Between 01:00 and 05:00, when nobody uses hot water, the heater used 0.31 kWh a night two months ago and 0.52 kWh now. That is energy spent only on keeping the tank hot, and it has grown by two thirds — inside eight weeks, which no change of season accounts for.
I can't see inside the heater, so these are things to check, not a diagnosis:
1. The thermostat setting. Has anyone turned it up? 2. A dripping hot tap or relief valve. Hot water leaving the tank all night looks exactly like this. 3. Insulation and limescale. If the tank has not been serviced for years, descaling it and checking the element is due anyway.The extra costs you about 11 EUR a month at the moment.
You: It hasn't been serviced in four years. I'll book it. What else?
Assistant: Three things you would not see on a chart.
1. When the heater runs. Of its 148 kWh, 96 fall in day hours at 0.35 EUR. If it has a timer and the tank lasts you through the day, heating at night at 0.15 EUR saves about 19 EUR a month, roughly 230 EUR a year.
2. When you wash. About 20 of the washing machine's 24 kWh fall between 18:00 and 21:00. Starting it after 23:00 saves about 4 EUR a month, 48 EUR a year.
3. What never switches off. In the quietest night hours your main supply still reads 0.24 kWh per hour. The heater and the kitchen account for 0.17 of it. The other 0.07 kWh is on no measured point: about 70 W, every hour of the year.
I can trust a figure this small because your main supply is on an STD-UI1 module. It notices that something is drawing current from 0.8 mA — above its own noise, which is 0.2 to 0.35 mA — and it counts energy from 4.8 mA. A Basic module states its accuracy from 5 % of the clamp's rating: on an SCT-013-030 that is 1.5 A. This night floor is about 0.3 A — roughly 1 % of that rating, below the range a Basic with a 30 A clamp states accuracy for. On this hub it is a measurement.
You: 70 watts is nothing.
Assistant: Per hour, yes. Over a year it is about 610 kWh, and at your tariff about 174 EUR. Chargers, standby electronics, a router, anything with a power brick.
One more detail, and here the hub's own limit shapes what I can say. Hourly records go back 60 days, so I can tell you this 0.07 has held steady for the last two months — and I cannot see from hourly records when it started. For older ground I have 400 days of daily totals, and yours have been drifting up since the spring. A daily total includes the daytime, so it cannot prove the night floor rose; it is consistent with something that runs around the clock. If you want the month it changed, switch the suspect off for a night and I will have the answer tomorrow.
You: The aquarium. And a second TV box. Can you tell which is which?
Assistant: Nothing measures them separately, but the STD-UI1 on your main supply is sensitive enough to see each one go. Pick a quiet moment, switch the TV box off at the wall and tell me. I'll read the live current before and after: even a 5 W standby is about 20 mA, well above the 4.8 mA where it starts counting energy.
Do the same with anything else you suspect, one device at a time. That is how you find the vampires without buying a meter for every socket.
You: TV box is off.
Assistant: Main supply dropped by 31 mA, about 7 W. Left on all year, that box costs you about 61 kWh, roughly 17 EUR, for doing nothing.
You: Deal. What should I do first?
Assistant: By what it is worth in a year, from your own figures:
Heater on night rate (if the tank allows) ~230 EUR Heater service, if the night loss goes back ~130 EUR Standby, if you cut half of it ~85 EUR Washing after 23:00 ~48 EUROne thing from outside the hub again: seasonal outlooks point to a colder winter than last, and outlooks are often wrong. If it holds, the heater's share will grow, which is one more reason to start there. The amounts above are estimates from one month, so ask me again in a month and I'll show what actually changed.
What that session shows
| In the session | The rule behind it |
|---|---|
| A year-on-year comparison of monthly totals | Daily totals go back 400 days, so a year ago is still on the hub |
| "0.31 a night two months ago", not last year | Hour-of-night detail needs hourly records, and those go back 60 days. A daily total includes the daytime, so it cannot prove a night floor rose |
| The weather archive named as outside the hub | The hub measures electricity and nothing else. Anything from elsewhere is labelled, every time |
| "things to check, not a diagnosis" | The hub sees current, not thermostats. A list of causes is a list of causes |
| A seasonal outlook called "often wrong" | A forecast is not a measurement, and saying so is part of the answer |
| 70 W found on no measured point | The figure is the main supply minus the points that explain it — which is only as good as the module on the supply |
| Switching one device off to identify it | Live current answers at once, and a standby load is well above the current the module reads from |
| "ask me again in a month" | One month's figures are an estimate of a year's, and the hub will have the real one |
What it cannot do
-
It cannot see inside an appliance. A heater that costs more tells you nothing about why, and the session says so rather than guessing.
-
It cannot go behind its own records. Hourly detail stops at 60 days, daily totals at 400, monthly at 36 months. These are the same whether the hub keeps history in its own flash or on the statistics chip — the chip changes how many points keep history, not how far back. → The statistics chip
-
It cannot split what nothing measures. The 70 W is a remainder, not a reading. Finding what makes it up is done by switching things off one at a time, which is what the session does.
-
It cannot price what it has not got. A point keeps records from the moment it was created, so a year-on-year answer needs a point that existed a year ago.
Where to go next
- What the hub offers and what it will let an assistant change → What an AI assistant reads and changes
- The phrasing that works → Things to ask it
- Set a hub up by talking to it → Set up a hub by talking to it