What an AI assistant reads and changes
The manifest is the list
The hub publishes what it offers in its MCP manifest (GET /api/llm/v1/manifest). That list grows with firmware
versions, so the hub itself — not a document — is the answer to what can my assistant do. The manifest is read
when a connection is made, so a restarted bridge reads the current list.
This page describes the kinds of thing that are there, which do not change when a new one is added.
If you are writing your own client, that manifest answers more than what: every tool in it says what it takes, and all but one say what they give back — so neither has to be found out by trial. The hub serves it to a token; without one it answers 401.
On firmware v1.3.0 the one exception is the tool that lists ESP-NOW nodes: it says its reply is an object and nothing more. That is a known gap rather than something you are reading wrong, and the next firmware release closes it.
🔸 Two things worth knowing before you start, because both cost an hour to discover. The extension file you install — the bridge's own bundle — carries no tool list at all: the tools come from the hub, so the manifest you want is the hub's, over HTTP, and not the file on your disk. And if you are writing an MCP client rather than talking to the hub directly, you will see each tool's input shape but not its reply shape: the bridge does not declare reply shapes on purpose, because one that turned out too strict would make an SDK reject a perfectly good answer from firmware we cannot correct in place. Nothing is missing from the answers themselves — they carry their values as structured content.
What it reads
| Family | What is in it |
|---|---|
| State and discovery | The hub itself, its health, its channels, live readings, events, the configuration and how that configuration is organised. |
| Analytics | Energy over a period, cost split by your own tariff, one period against another, the load profile, and what you import against what you export. Answers break down to the hour, and the hour in progress is included. |
| Context | The ready-made lines of enquiry the hub suggests for an analysis, and the price context for your region — the currency, and the day-ahead price sources and zones it knows about. That reference list is built into the firmware, not fetched. |
A cost is computed on the hub, from the tariff you set there — zones, taxes and the price of what you export included. If you have turned a day-ahead price source on, the hub fetches those prices itself and counts with them instead — that is the one thing the hub fetches from the internet, and it sends none of your readings when it does. → Prices · The assistant reads the figure the hub arrived at.
What it checks
These do not change anything. They look at what is there and tell you what they found.
| What it does | |
|---|---|
| Installation check | Checks the set-up itself: that every configured module answered, that points are attached to inputs, that no two modules share an address on a bus, and that the clock and time zone are set. Run it after any change you made by hand. It checks the set-up, not your figures. |
| Anomalies | Readings that stand out from the rest. |
| Find the channel | You switch a load on and off; the hub watches its channels once a second and names the one whose current moved with your steps. Useful when you do not know which clamp went on which circuit. The main supply is not one of the candidates — it is the reference, and the hub reports its step separately. If the supply saw your load and no other channel did, the answer says so: that circuit has no clamp of its own. |
| Identify the hub | The hub blinks its own status lights, so you can tell which hub you are talking to. Ten seconds by default; you can ask for longer, or stop it at once. A hub without status lights says so instead. |
What it changes
The two steps below are what protects you from an assistant that got something wrong — and an assistant can get something wrong. But they do not cover everything, and the difference matters.
In read mode your assistant does not have these tools at all. They are not offered to it and then refused — they are not in the list it was given, so it answers that it has no such tool. That is the expected answer, not a fault: widening what an assistant may do needs a second pairing code, not a retry. → Connect an AI assistant
Settings — proposed first, written after you agree
Channel names and roles, the clamp model of a point that already exists, the tariff plan with its zone prices and time windows, the day the monthly peak-demand period starts, the hub's time zone, the hub's own name and location.
A point's name, role and clamp are also given when the point is first created, and creating a point is a setup action — so they are set immediately that first time, and change in two steps afterwards.
A change arrives in two steps, and the first one is the one that protects you. The assistant proposes, and the hub answers with the exact change it would make — the fields, the values, and any warning that comes with them — together with a one-time confirmation that is good for ten minutes and is tied to that change and to the version it was based on. Once you agree, the assistant applies it with that confirmation. So you see what will happen before it happens, in the same conversation; and a proposal never used simply expires.
Setup actions — done when you ask
Adding a module on either bus, moving a module to another address, creating, moving or deleting a point, setting the pins of the second bus, restarting the hub.
These take effect at once. There is no diff and no confirmation from the hub: you asked, and it was done. Some apps will ask you first on their own, because the hub marks these as actions that change things — but that is your app's behaviour, not the hub's.
Most are undone by the opposite action: set the address back, move the point to the right input. A point's name, role and clamp are versioned and come back with a restore; modules, addresses and bus pins are not.
The main supply point is the exception to all of this: a hub starts with one, an assistant cannot delete it, and it cannot move the supply role onto or off any point. Setting a hub up means moving the supply point to the input your grid clamp is on. A three-phase supply set up as a point per phase has one supply point per phase, and that arrangement is made in the web app, not from a chat.
Undoing a change
The hub keeps eight versions of its settings, and every applied change is listed on the AI assistants page with a Restore button next to it. Restore previews exactly what it would undo before it does it.
⚠️ A restore brings back the whole version, not the one field you are thinking of. If you set the tariff, then set the time zone, then restore to the version before the tariff, you lose the time zone as well. Go back one step at a time and read the preview each time.
Both paths work. In the app you press Restore; from the chat an AI assistant can do it, in the same two steps
as any settings change — it proposes the rollback and applies it after you agree. The chat path needs config,
and it is refused while the hub is read-only. The button in the app is not: there it is you making the change.
One of the eight versions is treated differently: the state the hub was in before any AI assistant changed anything. On a hub that already had its settings when it came to v1.3.0, that state is kept and later changes do not push it out. On a hub whose settings were made after the AI interface was already in use, there is no such state to keep, and all eight are ordinary.
A restore never creates, deletes or moves points.
Correcting a mistake
| What went wrong | What to do | What happens to the history |
|---|---|---|
| The point is on the wrong input | Ask to move it | Kept. The id, name, role and recorded history stay; only the input changes |
| The point should not exist | Ask to delete it | 🔴 Erased. The hub frees the history slot, and what that point recorded is gone |
| The clamp rating was wrong | Ask to set the right one | Applies from that moment. Records already written are not recalculated, so the old readings stay as they were measured |
| A settings change was wrong | Restore, one step at a time | Settings only; the recorded measurements are untouched |
Deleting a point and restarting the hub are the two setup actions with no opposite action to undo them. Both are carried out as soon as they are asked for.
Clamp models come from a dated list inside the bridge. If your clamp is newer than the bridge you installed, the answer says the list is older than that model and asks you to update the bridge — it does not pick the nearest-looking one. That is on purpose: a nearest guess would be the wrong current rating on a real circuit in your home.
How to read the numbers
Five things look like mistakes and are not.
-
Energy and cost for the current hour are behind. They are updated every fifteen minutes, so the last few minutes may not be in the answer yet. Live readings are not behind — they are the current moment.
-
For energy and cost there is nothing finer than an hour. Ask for a shorter period and you still get hours. Peaks and prices are the exception — those are kept per 15-minute period, and an answer about them carries that period.
-
Cost rounds to the cent. Over a short period that is 0.00 or 0.01, and nothing is wrong.
- Anomaly detection needs history, and its two checks need different history. It is a tool an assistant has; the app has no anomaly search of its own. Unusual day compares a day with that point's 30-day average and needs 10 closed days of daily records — today does not count. Night standby rise compares the last seven days with the seven before, counting only the hours whose middle falls between 01:00 and 05:00, and needs at least eight such hours in each of those two weeks. Both thresholds are the same on every hub, and both are per point: a point you added yesterday has no history even though the hub has plenty.
⚠️ It is records, not days on the calendar. A hub switched on for two hours each afternoon will never collect night hours, so the night check will never have enough — waiting longer does not help.
Reading the answer, which is the part worth knowing: the hub does not simply go quiet when it has too little. It returns no findings, marks the answer as having gaps, counts how many checks had enough history, and says in words what is missing. So an empty answer with that count above nought means the checks ran and found nothing — all is well. The one case where silence does hide a gap: the note appears only when no check had enough data anywhere, so if an older point has enough and a new one does not, you hear nothing about the new one.
⚠️ On firmware 1.3.0 the hub's own note to an assistant says the night check needs fourteen days of hours. That is wider than the check really is, so an assistant may tell you to wait longer than you have to. A later firmware corrects the note; the check itself is unchanged. - In live values, power is not voltage times current. Two reasons, and both are normal. A module averages current, voltage and power separately, so the three figures in one answer are not three parts of one multiplication. And on a load that is not purely resistive, active power is below apparent power anyway — that ratio is the power factor. Multiply the volts by the amps and you get apparent power (V·A); what the hub reports as watts is active power.
The call log
The hub records every call: when, which assistant, which tool, the result and how long it took, with the applied
changes marked. You read it on the AI assistants page — the hub's own page and the app both show it. It holds the
newest fifty of the calls made since the hub last started, so a restart clears it, and an assistant with config
can restart the hub. The app's table of
paired assistants also shows, for each, when it was last used and how many calls it made today.
Things to ask it
Phrasing that works, grouped the way the tools are.
Reading "What is connected to my hub?" · "How much did the house use today, hour by hour?" · "Compare this hour with the last one." · "What did the water heater cost last week?"
Checking "Check my installation." · "I have just connected a module — find it." · "I am switching the kettle on and off now; tell me which channel sees it."
Changing "Name the point on I0 'Water heater', clamp SCT-013-030." · "Set the tariff: 0.35 by day, 0.15 at night from 23:00 to 07:00." · "Set the time zone to Europe/Berlin."
An assistant with read will answer the first two groups and tell you it cannot do the third.
→ A worked session that uses the first group on a hub with months of records: Finding where the money goes
Not paired yet?
Nothing on this page works until an AI assistant is paired with your hub. → Connect an AI assistant
Where your readings go
The hub answers on your own network and sends nothing out of it. Your AI assistant is a separate program: what it reads from the hub goes wherever that assistant sends it. If it runs in the cloud, your readings go to its service — the hub has no say in that. Pick the assistant you are willing to show your data to.
Troubleshooting
The assistant says a proposal has expired. A confirmation is good for ten minutes from the moment the change was proposed. Ask again and agree to the new one.
It says a change cannot be made, although it was paired with config.
The hub is in read-only mode, which overrides the scope of every paired assistant and covers everything an
assistant would write — settings, setup actions, a restart and its own rollback. It still answers with the diff,
marked as refused, so you can see what the change would have been. →
AI assistants
It says a proposal would change nothing. The value is already what you asked for. That is an answer, not an error.
Finding a channel does not name one. More than one clamp is seeing the same load. Switch something that only one channel can see.
Costs are there but the figures look wrong for the time of day. Check the hub's time zone: tariff windows follow the hub's clock, and a hub as it comes runs on UTC. → Time